Part Number Hot Search : 
51012 16161A MBR2060 2SC4855 1SMB5951 P6KE24CA MBR3015 48S15
Product Description
Full Text Search
 

To Download OS-LM10A-B1 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  os-lm10a linearlight flex data sheet benefits linear separable led strip on flexible printed circuit board with self-adhesive back ? small height ? available in various colors ? minimal heat generation ? applications edge-lighting of transparent or diffused materials ? path & contour marking ? illuminated signs ? walkways ? color voltage [v dc]* power [w]* radiance angle []* wavelength [nm] color temp [k]* lum. flux [lm]* current [a]* product number of leds technical operating data white 24 57,6 120 5400 k 540 2,4 os-lm10a-w1-854 600 white 24 57,6 120 4700 k 540 2,4 os-lm10a-w1-847 600 red 24 72,0 120 617 nm 930 3 os-lm10a-a 600 yellow 24 72,0 120 587 nm 1290 3 os-lm10a-y1 600 green 24 72,0 120 525 nm 675 3 os-lm10a-t1 600 blue 24 72,0 120 469 nm 170 3 OS-LM10A-B1 600 all data are related to the entire module due to the special conditions of the manufacturing processes of led the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical data. *) technical features modules optimized for use with osram optotronic power supplies. ? dimmable by pulse width modulation (pwm) with the electronic controller ot dim ? smallest unit of 10 leds can be cut out at regular intervals without damaging the rest of the module ? entire module consists of 600 leds ? wide viewing angle enables homogeneously illuminated surfaces ? size of printed circuit board ( lxwxh): 8400 mm x 10 mm x 3 mm ? size of smallest unit 10 led (lxw): 140 mm x 10 mm ? os-lm10a - seite 1 von 4
drawing operating temperature at tc-point [ c ] * storage temperature [ c ] * product voltage range [ v dc ] * reverse voltage [ v dc ] * minimum and maximum ratings os-lm10a-w1-854 23 25 25 ... -30 75 -40 85 ... ... os-lm10a-w1-847 23 25 25 ... -30 75 -40 85 ... ... os-lm10a-a 23 25 25 ... -30 85 -40 85 ... ... os-lm10a-y1 23 25 25 ... -30 85 -40 85 ... ... os-lm10a-t1 23 25 25 ... -30 75 -40 85 ... ... OS-LM10A-B1 23 25 25 ... -30 75 -40 85 ... ... exceeding maximum ratings for operation and storage temperature will reduce expected life time or destroy the led module. exceeding maximum ratings for operation voltage will cause hazardous overload and will likely destroy the led module. the temperature of the led module has to measured at the tc-point according to en60598-1 in a thermally constant status with a temperature sensor or a temperature sensitive label (available e.g. at rs-components). for exact location of the tc-point see drawing below. *) os-lm10a - seite 2 von 4
safety information the led module itself and all its components may not be mechanical stressed. ? assembly must not damage or destroy conducting paths on the circuit board. ? the led module incorporates no protection against: short circuits, overload, overheating. therefore it is absolutely necessary to operate the modules with a electronically stabilised power supply offering protection against the above mentioned safety risks. for dimming applications attention should be paid to specific references in "optotronic technical guide". parallel connection is highly recommended as safe electrical operation mode. serial connection is not recommended. unbalanced voltage drop can cause hazardous overload and demage the led module. installation of led modules (with power supplies) needs to be made with regard to all applicable electrical and safety standards. only qualified personnel should be allowed to perform installations. correct electrical polarity needs to be observed. wrong polarity will result in no light emission. ? ? ? osram optotronic power supplies are specifically designed with the necessary protection features for safe operation. when using other power supplies other than optotronic the following basic safety features are required, in addition to any other application specific concerns and local safety codes: short circuit protection ? overload protection overheat protection correct output voltage ? ? ? ? please ensure that the power supply is of adequate power to operate the total load. ? at mounting on metallic surfaces there have to be a electrical isolation at soldering points between module and the mounting surface. ? the maximum length of linearlight flex os-lm10a is 4200 mm with power feed at one end. the complete module 8400 mm can be operated with a two pole power feed in the middle of the module or from both ends, when do you use one power supply. ? pay attention to esd steps when mounting the module ? the module, as manufactured, has no conformal coating and therefore offers no inherent protection against corrosion. the ability to customize the length of the module by cutting at specifically marked points is a key feature of the product and hence the reason for no factory installed conformal coating. for these reasons, it is recommended that the user complete all module modifications first ( cutting, wiring) and then apply a conformal coating in the final stages of installation. ? damage by corrosion will not be honored as a materials defect claim. it is the users responsibility to provide suitable protection against corrosive agents such as moisture and condensation and other harmful elements. ? for applications involving exposure to humidity and dust the module must be protected by a fixture or housing with a suitable protection class. the module can be protected against condensation water by treatment with an appropriate circuit board grade conformal coating. the conformal coating should have the following features: - optical transparency - uv-resistance - thermal expansion matching the thermal expansion of the module 15-30*10^-6 cm/cm/k - low permeability of steam for all climatic conditions - resistance against corrosive environment the lacquer apl of the company electrolube http://www.electrolube.com met the conditions for the linearlight flex in our tests. os-lm10a - seite 3 von 4
assembly information ? solder connections should only be performed on designated solder pads ( marked "24v +/-"). during soldering, do not exceed the maximum soldering time of 10 seconds and the maximum soldering temperature of 260c. ? the smallest unit (140 mm- 10 leds) can be removed by cutting with scissors between the designated solder pads. ? the mounting of the module is facilitated by means of the double-sided adhesive on the back-surface of the module. care must be taken to provide a clean and dry mounting surface, free of oils or silicone coatings as well as dirt particle. the mounting substrate must have sufficient structural integrity. take care to completely remove the adhesive backing. once the module is appropriately positioned, press on the module with about 20n/cm2 ( refer to application techniques of 3m adhesive transfer tapes). ? the minimum bending radius is 2 cm. the module may be bent over a smaller radius but only in regions of the circuit board containing no electronic components and such bends should be made once and fixed in position to avoid cyclic fatigue. ? the thermal length expansion coefficent of the modul is 17*10^-6cm/cm/k. when installing in enviroments with large variations in temperature ( e.g. outdoor applications) and operating length of more than 2 m, the use of metallic mounting surfaces is necessary. otherwise it is advisable to use an additional thicker adhesive tape to absorb the stress of any mismatch in expansion coefficients. productgroup productname ean * s-unit * ordering guide linearlight flex os-lm10a-w1-854 4050300817170 8 linearlight flex os-lm10a-w1-847 4050300817156 8 linearlight flex os-lm10a-a 4050300938509 1 linearlight flex os-lm10a-y1 4050300946030 8 linearlight flex os-lm10a-t1 4050300946054 8 linearlight flex OS-LM10A-B1 4050300945491 8 ean: ordering number per single module s-unit: modules per shipping unit *) note: typical performance data are subject to change without any further notice, particularly as led technology evolves. related and further information the new dimension of light ? (in preparation) new creativity in lighting design led modules for illuminated signs ? 153 s07 e optotronic technical guide ? 130 t08 e optotronic data sheets ? www.osram.com sales and technical support osram opto semiconductors gmbh wernerwerkstrasse 2 d - 93049 regensburg germany www.osram-os.com osram gmbh hellabrunner strasse 1 d - 81536 mnchen germany www.osram.com +49 (0)89 6213-0 see web-page for local phone numbers os-lm10a - seite 4 von 4


▲Up To Search▲   

 
Price & Availability of OS-LM10A-B1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X